1. Memory function
This meter can store up to three measured values in memory for each measurement mode.
(incident light mode, -3 values, reflected light mode, -3 values). This feature can be used in the
following modes: ambient light (shutter speed priority only) EV, flash (with and without cord).
1. Press the Measuring button 19 and take a measure-
ment.
2. Press the Memory button 14 placing the measured
value in memory.
The number of values in memory is displayed on the
LCD. The f stop value corresponding to the measured
value is displayed in the analog section. By repeating
this operation, up to three values can be stored in
memory.
• Memory can be cleared by pressing the Memory clear
button 13 or changing measurement mode.
• The memory function cannot be used in "ambient light aperture priority mode" or "flash
cumulative mode."
• Measured values for the fourth and subsequent times will be displayed but cannot be
stored in memory.
• When the incident / reflected selection dial is moved, the memory remains on the analog
display, but when you press Memory clear button all values in memory are erased.
2.Averaging function
This displays the average of two or three of the values in memory.
1. Press the Measuring button 19 and take a
2. Press the Memory button placing the measured value
3. When the Ave/r EV button 4 is pressed, an average
value for the two or three measurements display on the
LCD. The value in memory and the average values are
displayed on the analog scale. An "A" appears in LCD
to indicate this is an average.
• The average mode can be canceled by pressing the
Ave/
r EV button.
3. Brightness difference function
This function is useful for evaluating studio lighting and checking the evenness of the lighting set-up
across the subject area.
Take a measured value at a certain point as a standard value. The difference between the standard
value and a new measured value is displayed as EV and the f-stop in analog scale.
Example of adjusting lights using brightness measurement with shutter speed priority mode.
1. Turn the Lumisphere UP/DOWN ring 1
to lower it to
the DOWN position.
2. Turn any secondary light source off. Point the
Lumisphere toward the main light source, from the
position of the subject and take a measurement. Press
the Memory button 14
and store the value in memory.
3. Press the Average/
r EV button and display the "A"
mark on the LCD.
Comentarios a estos manuales